Article number
306300

EDM 201 multimedia CATV

EDM 201 Selective COAX Multimedia CATV

To be used in interactive CATV networks, in well isolated branch lines from the CATV multi-tap

  • High isolation between TV and DATA port - avoids interference produced from modem operation
  • Unsymmetrical and selective coupling of upstream/downstream signals to DATA port enables lowest insertion loss as well as zero intermodulation of the upstream signal
  • Reliable SMD technology
  • Shielding comply to Class A+ (Class A+10dB) according to EN 60728-2 (5.5)

ORDER INFORMATION

EAN Number5702663063006

CONNECTORS

Connector IN-OUTSpring Clamp Termination
Connector TVIEC-male
Adaptable Cable Diameters - Inner Conductor 0.58...1.15 mm
Adaptable Cable Diameters - F-female 0.6...1.13 mm
Adaptable Cable Diameters - Outer Conductor 3.7...5.8 mm
Adaptable Cable Diameters- Jacket 4.5...7.2 mm

FREQUENCY RANGE

Frequency Range TV 258...1200 MHz
Frequency Range DATA 5...204 / 258...1794 MHz

CHARACTERISTICS

Outlet TypeTerminated

LOSS

Through Loss IN-TV 4.2 (@258...1218MHz) 54 (@<204MHz) 65 (@<30MHz) dB
Through Loss IN-DATA 1 (@5...204MHz) 4.2 (@258...1218MHz) 5.2 (1218...1794MHz) dB

ISOLATION

Isolation TV-DATA 56 (@<85MHz) 53 (@85...204MHz) 20 (@258...862MHz) 18 (@862...1794MHz) dB

RETURN LOSS

Return Loss IN 14 (@<204MHz) 18 (@258...1218MHz) 15 (@1218...1794MHz dB
Return Loss DATA 16 (@<204MHz) 14 (@258...1218MHz) 12 (@1218...1794MHz) dB
Return Loss TV 20 (@258...300MHz) 18 (@300...1218MHz) dB

SHIELDING

Shielding @ 30-300 MHz ≥ 95.0 dB
Shielding @ 300-470 MHz ≥ 90.0 dB
Shielding @ 470-1000 MHz ≥ 85.0 dB
Shielding @ 1000...2400 MHz ≥ 65.0 dB

ELECTRICAL

Impedance 75 Ω

MECHANICAL

Tensile Strength - Inner Conductor 1 (Ø) > 25 @ 0.75mm N/mm2
Tensile Strength - Inner Conductor 2 (Ø) > 50 @ 1.13mm N/mm2
Plug-in Strength - with ø 1,1 25 N
Main materialZinc diecast
Packaging Height 0.035 m
Packaging Width 0.071 m
Packaging Depth 0.071 m
Packaging Volume 0.000 m3
Net Weight 0.096 kg
Tara Weight 0.008 kg
Total Weight 0.104 kg

OPERATIONAL

CertificationEN 50083-1, EN 50083-2
Screening EfficiencyEN50083-2 (Class A+10dB)
MTBF (mean time between failures) >1.000.000 hours
Temperature - operating -25...55 °C
Temperature - storage -25...55 °C
Temperature - shipping -40...70 °C