RG 11 - LSZH - 500m plywood drum

  • Rated according to CPR EN50575 Firestandard Dca

TRIAX RG 11 cables are ideal for long cable runs in for instance residential buildings. TRIAX RG11 cables are made of high quality materials to secure high stability for many years to come. To protect signal quality the cables are highly shielded.

The Low Smoke Zero Halogen jacket is ideal where fire resistance is a requirement.

  • Class A+
  • Full copper inner conductor
  • Long lifetime due to high quality materials

ORDER INFORMATION

EAN Number5702661502415

MECHANICAL

Cable length 500 m
Minimum bending radius - single/repeated 50/100 mm
ColourWhite
Packaging Height 0.325 m
Packaging Width 0.600 m
Packaging Depth 0.600 m
Packaging Volume 0.000 m3
Net Weight 0.118 kg
Tara Weight 0.000 kg
Total Weight 0.118 kg

CONSTRUCTION

Inner conductor - materialCu
Inner conductor - dimension 1.7 ± 0.01 mm
Dielectric - materialFoam PE
Dielectric - dimension 7.2 ± 0.05 mm
1. Shield foil – materialAlu/PET bonded
2. Shield braid - materialCuSn
2. Shield braid - coverage 55 %
3. Shield foil – materialAlu/PET bonded
Jacket - materialLSZH
Jacket – dimension 10.2 ± 0.1 mm

OPERATIONAL

ApplicationOutdoor
Fire ClassEN 50575 (Dca)
Fire SubClassS2, d1, a1
DoP numberTR0003
Notified Body2479
Screening EfficiencyEN50117 (Class A+)
Suitable for
  • F-compression connector RG11-CX3-11.3 QM, 25 pcs. box
  • F-compression connector RG11-CX3-10.5 QM, 25 pcs. box
Temperature - operating -20...70 °C
Temperature - storage -20...70 °C
Temperature - shipping -20...70 °C

TRANSFER IMPEDANCE

Transfer Impedance @ 5-30 MHz < 2,5 mΩ/m

SHIELDING

Screening attenuation @ 30-1000 MHz > 120 dB
Screening attenuation @ 1000-2000 MHz > 115 dB
Screening attenuation @ 2000-3000 MHz > 100 dB

ELECTRICAL

Impedance 75 ± 3 Ω
Capacity 52 ± 3 pF/m
Velocity ratio 82 %
Inner DC resistance < 7.5 Ω/km
Outer DC resistance < 9 Ω/km
Insulation Resistance > 10^4 MΩ/km

LOSS

Attenuation (20°C/100mtr) @ 5 MHz 0.9 dB
Attenuation (20°C/100mtr) @ 50 MHz 2,7 dB
Attenuation (20°C/100mtr) @ 200 MHz 5,6 dB
Attenuation (20°C/100mtr) @ 470 MHz 8,8 dB
Attenuation (20°C/100mtr) @ 862 MHz 12,3 dB
Attenuation (20°C/100mtr) @ 1000 MHz 13,1 dB
Attenuation (20°C/100mtr) @ 1750 MHz 18.0 dB
Attenuation (20°C/100mtr) @ 2150 MHz 20.2 dB
Attenuation (20°C/100mtr) @ 2400 MHz 22.3 dB
Attenuation (20°C/100mtr) @ 3000 MHz 24.3 dB

RETURN LOSS

Structural return loss @ 5-470 MHz > 26 dB
Structural return loss @ 470-1000 MHz > 23 dB
Structural return loss @ 1000-2000 MHz > 20 dB
Structural return loss @ 2000-3000 MHz > 20 dB